Technology and excellence in detection

We invite you to know all of our product list and its technical characteristics. All of them has been tested and characterized in the facilities of the Comisión Nacional de Energía Atómica (CNEA), under the supervision of its scientific personnel.


Post sale assistance


You will never be alone, Solydes will promptly take care any difficulty to ensure the success of your project. Our specialized staff is willing to assist and bring you all the information regarding our detectors.
 
NEUTRON DETECTORS
 
CIC-40
Compensated Ionization Camera with B10 as converter.

External Diameter:
Ø 40 mm. Sensible Length: 261 mm.
Body Length:
450 mm. Sensibility: 10-14 amp n-1 cm2 seg.

 
Material:
Aluminum.
Application:
Neutron detector used for controlling and safety in the operation of nuclear reactors.
 
CF-7
Fission counter with U235 as converter.

External Diameter:
Ø 7,6 mm. Sensible Length: 26 mm.
Body Length:
57 mm.
Sensibility:
3,10-7 cps/nv.

 
Material:
Iron.
Application:
Small size fission c ounter with ultra low sensibility for experiments in high flux in nuclear reactors.
 
CF-19
Counter and fission camera with U235 as converter.

External Diameter: Ø 19 mm.
Sensible Length: 49 mm.
Body Length: 160 mm. Sensibility: 0,01 cps/nv.

 
Material: Stainless steel.
Application:
Miniature Counter and fission camera used as beam neutron monitor in nuclear reactors.
 
CFP-35
Fission counter with U235 as converter.

External Diameter:
Ø 35 mm. Sensible Length: 250 mm.
Body Length:
330 mm.
Sensibility:
0,15 cps/nv.

 
Material:
Stainless steel.
Application:
Neutron detector used at the start up of nuclear reactors of investigations and radioisotopes production.
 
CFC-51
Campbell fission camera with U235 as converter.

External Diameter:
Ø 58,8 mm.
Sensible Length:
250 mm.
Body Length:
330 mm.
Sensibility:
0,15 cps/nv.

 
Material:
Stainless steel.
Application: Neutron d etector used in the control of the all the range of nuclear reactors (Start up, medium range and power).
 
GAMMA DETECTORS
 
CIG-35
High range ionization camera.

External Diameter:
Ø 35 mm. Sensible Length: 170 mm.
Long. Body:
250 mm.
Sensibility:
10-10 amp R-1 H.
Material: Stainless steel.
 
Application: Its small size and operation range allows to be used as an area monitor o be taken as manipulators for the search of missing sources within the radioisotopes production cell.
 
CIG-89
Medium range Ionization Camera.

External Diameter:
Ø 89 mm. Sensible Length: 220 mm.
Body Length:
320 mm (variable).
Sensibility:
10-9 amp R-1 H.
Material: Stainless steel.
 
Application: Gamma detector of high sensibility and very broad range of operation with the capacity to operate in severe environmental conditions. Variable length.
 
CIG-120
High range Ionization Camera.

External Diameter:
Ø 120 mm. Sensible Length: 126 mm.
Body Length:
170 mm.
Sensibility:
10-9 amp R-1 H.
Material: Stainless steel.
 
Application: Gamma detector of high sensibility and very broad range of operation with the capacity to operate in severe environmental conditions.
 
CFP 114 A

Well ionization camera for using as activimeter in nuclear medicine.

Well Dimension :
60 mm diameter / 245 mm depth.
External dimension:
114 mm diameter / 381 mm length.
Structural material:
aluminum.
Well m aterial:
aluminum.
Gas collector:
argon 4 kg/cm2.
Electrical Structure:
Kept.
Polarization:
chassis and well.

 
Work Tension:
300 volt typical / 800 volt maximum.
Signal Range:
10 -14 to 10 -6 amp.
Activity Range:
1 mCi to 100 Ci.
Energy Range:
20 KeV to 3 MeV.
Sensibility (Cs-137):
6.67 10 -8 A/Ci.
Sensibility (I -125):
7.5 109 U/A.
(Cs-137):
4.2 1010 U/A.
Shielding:
Lead iron / accessory.
 
CFP 114 B
Well ionization camera to be used in braquitherapy treatment.

Well Dimension:
35 mm. diameter / 245 mm depth.
External dimension:
114 mm. diameter / 381 mm length.
Structural material:
aluminum.
Well material:
aluminum.
Gas collector:
argon 4 kg/cm2
Electrical Structure:
Kept.
Polarization:
chassis and well.



 
Work Tension: 300 volt, typical / 800 volt maximum.
Signal Range: 10 -14 to 10 -6 amp
Activity Range: 1 mCi to 100 Ci
Energy Range: 20 KeV to 3 MeV
Sensibility (Cs-137): 1.02 10-7 A/Ci.
Sensibility (I -125): 3.9 109 U/A
(Cs-137): 2.7 1010 U/A.
Shielding: lead iron / accessory.
 
CFP 111 B
Well ionization camera to be used in braquitherapy treatment.

Well Dimension:
35 mm diameter / 156 mm depth.
External dimension:
101 mm diameter / 334 mm length.
Structural material:
acrylic.
Well material:
acrylic.
Gas collector:
air 1 atm.
Electrical Structure:
Kept.
Polarization:
internal.

 
Work Tension: 300 volt typical / 800 volt maximum.
Signal Range: 10 -14 to 10 -6 amp.
Activity Range: 10 mCi to 10 Ci.
Energy Range: 20 KeV to 3 MeV.
Sensibility (Cs-137): 9.5 10 -9 A/Ci.
Sensibility (I -125): 2.85 1011 U/A.
(Cs-137): 2.81 1011 U/A.
Shielding: iron, incorporated.
 
AREAS OF USE
Nuclear: CIC-40, CFC-51, CFP-35, CF-7, CF-19, CIG-89, CIG-120, CIG-35.
Radiological safety : CIG-89, CIG-120, CIG-35.
Nuclear Medicine: Activimeters: CFP-114 A / Braquitherapy: CFP-114 B, CFP-111B.
BNCT (therapy by neutron capture in Boron): CF-7, CF-19.